Please use this identifier to cite or link to this item:
https://repository.unad.edu.co/handle/10596/69138Full metadata record
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.advisor | Jamaica Guio, Edna Rocío | |
| dc.coverage.spatial | cead_-_valledupar | |
| dc.creator | Acosta Vergara, Andrea Camila | |
| dc.creator | Calles Gálvez, Andrea | |
| dc.creator | Morales Herrera, Beatriz Helena | |
| dc.creator | Cardona Rodríguez, Bryan | |
| dc.creator | Tovar García Eliana, Liseth | |
| dc.date.accessioned | 2025-05-31T06:12:11Z | |
| dc.date.available | 2025-05-31T06:12:11Z | |
| dc.date.created | 2025-05-28 | |
| dc.identifier.uri | https://repository.unad.edu.co/handle/10596/69138 | |
| dc.description.abstract | La inteligencia artificial (IA) ha transformado significativamente el campo de la imagenología médica, especialmente en modalidades como la tomografía computarizada (TC) y la resonancia magnética (RM). Esta investigación, de tipo documental y enfoque cualitativo, analiza las causas y consecuencias de la limitada efectividad en la calidad de imagen, atribuida a la ineficiente aplicación de algoritmos de optimización basada en IA. A través de la revisión sistemática de literatura científica, se identificaron los principales algoritmos utilizados, como U-Net, GANs y técnicas evaluativas, así como las barreras técnicas, éticas, operativas y administrativas que dificultan su implementación en entonos clínicos reales. Se evaluó también la efectividad de dichos algoritmos mediante parámetros como SNR, PSNR y SSIM, evidenciando mejoras significativas en la calidad técnica de imagen, aunque aún con escasa validación clínica. Finalmente, se proponen estrategias para una integración ética, segura y eficaz de la IA en el procesamiento de imágenes médicas en el contexto colombiano, resaltando la implementación de la capacitación profesional, en desarrollo normativo y la colaboración interdisciplinaria. | |
| dc.format | ||
| dc.title | Limitaciones en la mejora de calidad de imágenes en tomografía computarizada (TC) Y resonancia magnética (RM) por la subutilización de algoritmos de optimización basados en inteligencia artificial (IA) | |
| dc.type | Diplomado de profundización para grado | |
| dc.subject.keywords | Algoritmos de Optimización | |
| dc.subject.keywords | Inteligencia Artificial | |
| dc.subject.keywords | Resonancia Magnética | |
| dc.subject.keywords | Tomografía Computarizada | |
| dc.description.abstractenglish | Artificial intelligence (AI) has significantly transformed the field of medical imaging, particularly in modalities such as computed tomography (CT) and magnetic resonance imaging (MRI). This documentary research, based on a qualitative approach, analyzes the causes and consequences of the limited effectiveness in image quality, attributed to the inefficient application of AI-based optimization algorithms. Through a systematic review of scientific literature, the main algorithms used—such as U-Net, GANs, and evolutionary techniques—were identified, along with the technical, ethical, operational, and administrative barriers that hinder their implementation in real clinical settings. The effectiveness of these algorithms was also evaluated using parameters such as SNR, PSNR, and SSIM, revealing significant improvements in technical image quality, although clinical validation remains limited. Finally, strategies are proposed for the ethical, safe, and effective integration of AI in the processing of medical images in the Colombian context, emphasizing the importance of professional training, regulatory development, and interdisciplinary collaboration. | |
| Appears in Collections: | Diplomado de Profundización en Control de la Calidad en Radiología Digital | |
Files in This Item:
| File | Description | Size | Format | |
|---|---|---|---|---|
| eltovarga.pdf | 493.39 kB | Adobe PDF | ![]() View/Open |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.
