Please use this identifier to cite or link to this item:
https://repository.unad.edu.co/handle/10596/82128Full metadata record
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.advisor | Jamaica, Edna | |
| dc.coverage.spatial | udr_-_Cúcuta | |
| dc.creator | Chacon Rivera Andrea Valentina | |
| dc.creator | Rey Arciniega Cristhian Fabian | |
| dc.creator | Monroy Pérez Liseth | |
| dc.creator | Torres Tolosa Sergio Andrés | |
| dc.creator | Díaz Calderon Sergio Ivan | |
| dc.date.accessioned | 2026-06-09T23:02:55Z | |
| dc.date.available | 2026-06-09T23:02:55Z | |
| dc.date.created | 2026-06-02 | |
| dc.identifier.uri | https://repository.unad.edu.co/handle/10596/82128 | |
| dc.description.abstract | La presente investigación analiza los protocolos de cifrado y las estrategias de ciberseguridad más efectivos para la transmisión de datos dosimétricos en redes hospitalarias que usan Internet de las Cosas (IoT) en radiología. A través de una metodología descriptiva y documental basada en revisión literaria, reportes técnicos y estándares internacionales, se estudian los mecanismos de seguridad aplicados a la comunicación entre dispositivos IoT, sistemas RIS, PACS y plataformas interoperables. El análisis se centra en la integridad, confidencialidad, disponibilidad y autenticidad de los datos clínicos, la identificación de vulnerabilidades de accesos no autorizados, fallas de interoperabilidad, ataques de red y manipulación de información dosimétrica. Los resultados indican que los protocolos de cifrado más robustos son aquellos que integran cifrado extremo a extremo, AES, TLS, criptografía liviana, modelos Zero Trust y mecanismos de autenticación federada, especialmente en entornos IoT con limitaciones de hardware o con comunicaciones de alta frecuencia. Asimismo, la literatura destaca que la eficacia de estos protocolos depende de su correcta implementación, de la arquitectura de red y del grado de interoperabilidad con estándares como HL7, FHIR y DICOM. También se evidencia que la falta de estandarización y la fragmentación de sistemas hospitalarios comprometen la integridad de los registros de dosis y afectan la seguridad del paciente. Se concluye que fortalecer la infraestructura tecnológica, estandarizar protocolos y adoptar modelos criptográficos avanzados es esencial para garantizar una transmisión segura y continua de los datos dosimétricos para reducir vulnerabilidades y optimizar la protección radiológica del paciente. | |
| dc.format | ||
| dc.title | Revisión documental de los protocolos de cifrado y mecanismos de ciberseguridad aplicados al envío de datos dosimétricos en entornos hospitalarios IoT | |
| dc.type | Diplomado de profundización para grado | |
| dc.subject.keywords | IoT | |
| dc.subject.keywords | Dosimetría | |
| dc.subject.keywords | Cifrado | |
| dc.subject.keywords | Ciberseguridad | |
| dc.subject.keywords | Gestión de Imágenes Médicas | |
| dc.description.abstractenglish | This research analyzes the most effective encryption protocols and cybersecurity strategies for the transmission of dosimetric data in hospital networks that use the Internet of Things (IoT) in radiology. Through a descriptive and documentary methodology based on literature review, technical reports, and international standards, the study examines security mechanisms applied to communication between IoT devices, RIS, PACS, and interoperable clinical platforms. The analysis focuses on the integrity, confidentiality, availability, and authenticity of clinical data, as well as the identification of vulnerabilities related to unauthorized access, interoperability failures, network attacks, and manipulation of dosimetric information. The results indicate that the most robust encryption protocols are those that incorporate end-to-end encryption, AES, TLS, lightweight cryptography, Zero Trust models, and federated authentication mechanisms, particularly in IoT environments with hardware limitations or high-frequency communication requirements. The literature further highlights that the effectiveness of these protocols depends on proper implementation, network architecture, and the degree of interoperability with standards such as HL7, FHIR, and DICOM. The findings also show that the lack of standardization and the fragmentation of hospital systems compromise the integrity of dose records and negatively impact patient safety. It is concluded that strengthening technological infrastructure, standardizing protocols, and adopting advanced cryptographic models are essential to ensure secure and continuous transmission of dosimetric data, reduce vulnerabilities, and optimize radiological protection for patients. | |
| dc.subject.category | Tecnología en Radiología e Imágenes Diagnósticas | |
| Appears in Collections: | Diplomado de Profundización en Control de la Calidad en Radiología Digital | |
Files in This Item:
| File | Description | Size | Format | |
|---|---|---|---|---|
| AVCHACONR.pdf | 749.93 kB | Adobe PDF | View/Open |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.