    Evaluación de la Amniocentesis Precoz en una Institución Brasileña de Diagnóstico Prenatal

    Amniocentesis Early Assessment in an Institution of Prenatal Diagnosis in Brazil

    Amniocentesis Early Assessment in an Institution of Prenatal Diagnosis in Brazil

    Thumbnail
    QRCode
    Share
    Author
    Bernal Parra, Luz Mery
    Publisher
    Universidad Colegio Mayor de Cundinamarca

    Citación

           
    TY - GEN T1 - Amniocentesis Early Assessment in an Institution of Prenatal Diagnosis in Brazil T1 - Evaluación de la Amniocentesis Precoz en una Institución Brasileña de Diagnóstico Prenatal AU - Bernal Parra, Luz Mery UR - https://repository.unad.edu.co/handle/10596/29902 PB - Universidad Colegio Mayor de Cundinamarca AB - ER - @misc{10596_29902, author = {Bernal Parra Luz Mery}, title = {Amniocentesis Early Assessment in an Institution of Prenatal Diagnosis in BrazilEvaluación de la Amniocentesis Precoz en una Institución Brasileña de Diagnóstico Prenatal}, year = {}, abstract = {}, url = {https://repository.unad.edu.co/handle/10596/29902} }RT Generic T1 Amniocentesis Early Assessment in an Institution of Prenatal Diagnosis in Brazil T1 Evaluación de la Amniocentesis Precoz en una Institución Brasileña de Diagnóstico Prenatal A1 Bernal Parra, Luz Mery LK https://repository.unad.edu.co/handle/10596/29902 PB Universidad Colegio Mayor de Cundinamarca AB OL Spanish (121)
    Bibliographic managers
    Refworks
    Zotero / EndNote / Mendeley
    BibTeX
    CiteULike
    Metadata
    Show full item record
    Abstract
    A pesar de que la amniocentesis tradicional (AT) es un procedimiento de comprobada seguridad y confianza, el diagnóstico citogenético resultante está disponible en un periodo tardío de la gestación. La amniocentesis realizada entre 12 y 14 semanas presenta algunas ventajas sobre la AT y otras relativas a la muestra de vellosidad corial (AVC), pero su seguridad requiere cuidadoso análisis. El objetivo de este estudio fue evaluar el riesgo de pérdida fetal y de anomalías congénitas en un grupo de 479 embarazadas (un único feto), sometidas a la amniocentesis precoz (12-14 6/7 semanas). Con procedimientos monitorizados con ultrasonografía se recolectó aproximadamente 1ml de líquido amniótico por semana de edad gestacional, la edad materna media fue de 35,7 ± 4,58 años. La principal indicación para la realización del procedimiento fue edad materna de 35 años o más (un 66,1%). Se realizó un seguimiento completo del 90,2% (432/479) de las pacientes.El líquido amniótico fue obtenido con éxito en la primera tentativa en 406 casos (94,0%). La tasa de pérdidas fetales fue del 4,9%, de ese porcentaje, un 2,9% ocurrieron hasta la 28a semana. Las diferencias observadas para las tasas de pérdidas fetales en las diferentes edades maternas no fueron estadísticamente significativas, la distribución de pérdidas fetal por categoría de edad gestacional no presentó diferencias significativas. De las pacientes, un 5,1% y un 2,3% relataron pérdida de líquido amniótico y sangrado, respectivamente. Estos hallazgos estuvieron significativamente asociados a la pérdida fetal. Se observaron ocho casos (2,0%) de problemas respiratorios y dos (0,5%) de anomalías músculo-esqueléticas. Nuestros datos sugieren un aumento de complicaciones y pérdidas fetales en edades gestacionales más precoces, especialmente ...
    College
    http://hemeroteca.unad.edu.co/index.php/nova/article/view/513/977
    /*ref*/Tabor A., Madsen M, Obel E.B., Philip J., Bang J., Noergard-Peterson B. (1986). Randomised controlled trial of genetic amniocentesis in 4606 low-risk women. Lancet i: 1287-1293.
    /*ref*/Dallaire L., Lortie G., Des Rochers M., Clermont R., Vachon C. (1995). Parental reaction and adaptability to the prenatal diagnosis of fetal defect or genetic disease leading to pregnancy interruption. Prenat. Diagn., 15:249-259.
    /*ref*/Hanson F.W., Zom E.M., Tennant F.R., Marionos S., Samuels S. (1987). Amniocentesis before 15 weeks gestation: Outcome, risks, and technical problems. Am. J. Obstet. GynecoI., 156:1524-1531.
    /*ref*/Eiben B., Goebel R., Hansen S., Hammans W. (1994). Early amniocentesis. A cytogenetic evaluation of over 1500 cases. Prenat. Diagn., 14:497-501.
    /*ref*/Elejalde B.R., de Elejalde M.M., Acuna J.A., Thelen D., Tiujillo C., Kamnann M. (1990).
    /*ref*/Prospective study of amniocentesis performed between weeks 9 and 16 of gestation: Its feasibility, risks, complications and use in early genetic prenatal diagnosis. Am. J. Med. Genet., 35:188-196.
    /*ref*/Gollop T.R., Naccache N.F., Pieri P.C. (1993). Amniocentese Precoce (12-15 semanas) com resultados rápidos: Uma realidade no lnstituto de Medicina Fetal. Femina., 21:680- 682.
    /*ref*/Henry G.P., Miller W.A. (1992). Early Amniocentesis. J. Repmd. Med., 37(5):396-402.
    /*ref*/Nadyr Fernandes Naccache, Instituto de Medicina Fetal y Genética Humana
    /*ref*/Nicolaides K.H., Brizot M.L., Patel F., Snijders R.J. (1996). Comparison of Chorion Villus Sampling and Early Amniocentesis for karyotyping in 1492 singlenton pregnancies. Fetal. Diagn. Ther., 11:9-15.
    /*ref*/Cederholm M., Axelsson O. (1997). A prospective comparative study on transabdominal chorionic villus sampling and amniocentesis performed at 10-13 weeks gestation. Prenat. Diagn., 17(4):311-317..
    /*ref*/Nagel H.T.C., Vandenbussche F.P., Keirse M.J., Oepkes D., Oostewijk J.C., Beverstock G., Kanhai H.H. (1998). Amniocentesis before 14 completed weeks as an altemative to transabdominal chorionic villus sampling: A controlled trial with infant follow-up. Prenat. Diagn., 18:465-475.
    /*ref*/The Canadian Early and Mid-Trimester Amniocentesis Trial (CEMAT) Group. (1998). Randomised trial to asses safety and fetal outcome of early and midtrimester amniocentesis. Lancet, 351:242-247.
    /*ref*/Crandall B. F., Kulch P., Khalil T. (1994). Risk assessment of amniocentesis between 11 and 15 weeks: Comparison to later amniocentesis controls. Prenat. Diagn., 14:913-919.
    /*ref*/Eiben B., Hammans W., Hansen S., Trawicki W., Osthelder B., Stelzer A., Jaspers KD., Goebel R. (1997). On the complication risk of Early Amniocentesis versus Standard Amniocentesis. Fetal. Diagn. Ther., 12:140-144.
    /*ref*/Tavares P., Tavares A., Rendeiro P., Palmares C. (1998). Comparison between CVS and early amniocentesis. Prenat. Diagn., 18(1):87. Letters to editor.
    /*ref*/Sato K., lzuta M., Kojima T., Miyakawa T., Yokoo l., Takahashi K, Tametika S., Okuno T.,
    /*ref*/Saitou R., Toubai H. (1992). Early amniocentesis risk and laboratory evaluation. Acta.Obstet. Gynaecol. Jpn., 44:1285-1288.
    /*ref*/Stripparo L., Buscaglia M., Longatti L., Ghisoni L., Dambrosio F., Guemeri S., Roselia
    /*ref*/F., Lituania M., Cordones M., De Biasio P., Passamonti U., Gimeiii G., Cuoco C. (1990). Genetic amniocentesis; 505 cases performed before the sixteenth week of gestation. Prenat. Diagn., 10:359-364.
    /*ref*/Hanson F.W., Tennant F.R, Hune S., Brookhyser K. (1992). Early amniocentesis: Outcome, risk, and technical problems at 12.8 weeks or less. Am. J. Obstet. GynecoI., 166:1707-1711.
    /*ref*/Johnson J.M., Wilson R.D., Singer J., Winsor E., Harman C., Armson B.A., Benzie
    /*ref*/R., Dansereau J., Ho M.F., Mohide P., Natale R., Okun N. (1999). Technical factors in early amniocentesis predict adverse outcome. Results of the Canadiam Early (EA) versus Mid-trimester (MA) Amniocentesis Trial. Prenat. Diagn., 19:732-738.
    /*ref*/Daniel A., NG A., Kuah K.B., Reiha S., Malafiej P. (1998). A study of early amniocentesis for prenatal cytogenetic diagnosis. Prenat. Diagn., 18(1):21-28.
    /*ref*/Schulman L.P., Elias 8., Simpson J.L. (1991). Early amniocentesis: Complications in initial 150 cases compared to complications in initial 150 cases of transabdominal chorioric villus sampling. Am. J. Hum. Genet, 49:231.
    /*ref*/Opitz, J.M. Tópicos recentes de genética clinica. (1984). Sociedade Brasileira de Genética Ribeirão Preto. São Paulo.
    /*ref*/Boué J., Boué A., Lazar P. (1975). Retrospective and prospective epidemiological studies of 1500 karyotyped spontaneous human abortions. Teratology., 12:11-26.
    /*ref*/Fitzsimmons J., Jackson D., Wapner R. Jackson L. (1983). Subsequent reproductive outcome in couples with repeated pregnancy loss. Am. J. Med. Genet., 16:583-587.
    /*ref*/Stray-Pederson B., Stray-Pederson S. (1984). Etiologic factors and subsequent reproductive performance in 195 couples with a prior history of habitual abortion. Am. J. Obstet. Gynecol., 148:140-146.
    /*ref*/Goldberg J.D., Porter A.E., Golbus M.S. (1990). Current assessment of fetal losses as a direct consequence of chorionic villus sampling. Am. J. Med. Genet, 35:174-177.
    /*ref*/Nevin J., Nevin N.C., Doman J.C., Sim D., Armstrong M.J. (1990). Early amniocentesis:
    /*ref*/Experience of 222 consecutive patients, 1987- 1988. Prenat. Diagn., 10:79-83.
    /*ref*/Schulman L.P., Elias 8., Phillips O.P., Grevengood C., Dungan J.S., Simpson J.L. (1994).
    /*ref*/Amniocentesis performed at 14 weeks gestation or earlier. Comparison with first-trimester transabdominal chorionic villus sampling. Obstet. Gynecol., 83:543-548.
    /*ref*/Frates M.C., Benson C.B., Doubilet M. (1993). Pregnancy outcome after a first trimester sonogram demonstrating fetal cardiac activity. J. Ultrasound. Med., 12:383-386.
    /*ref*/Wilson R.D., Kendrick V., Wittmann B.K., McGiIIivray B.C. (1986). Spontaneous abortion and pregnancy outcome after normal firsttrimester ultrasound examination. Am.J.Obstet. Gynecol., 67:352-355.
    /*ref*/Brumfield C.G., Lin S., Conner W., Cosper P., Davis R.O., Owen J. (1996). Pregnancy outcome following genetic amniocentesis al 11-14 versus 16-19 weeks gestation. Obstet. Gynecol., 88(1): 114-118.
    /*ref*/Sundberg K., Bang J., Smidt-Jensen 8., Brocks V., Lundsteen C., Pamer J., Keiding N.,
    /*ref*/Philip J. (1997). Randomised study of risk of fetal loss related to early amniocentesis versus chorionic villus sampling. Lancet., 350:697-703.
    /*ref*/Eiben B., Hammans W., Trawicki W., Goebel R. (1998). Early Amniocentesis versus Chorionic Villus Sampling. Prenat. Diagn., 18:405-406, Letters to the editor.
    /*ref*/Tharmaratnam S., Sadek S., Steele E.K., Harper M.A., Stewart F.J., Nevin J., Nevin N.C.,
    /*ref*/Doman J.C. (1998). Early amniocentesis: Efect of removing a reduced volume of amniotic fluid on pregnancy outcome. Prenat. Diagn., 18:1773-778.
    /*ref*/Tharmaratnam S., Sadek S., Steele E.K., Harper M.A., Nevin N.C., Doman JACI
    /*ref*/. Transplacental early amniocentesis and pregnancy outcome. Br. J. Obstet. Gynaecol., 105(2):228-230.
    /*ref*/Diaz M., De la Cueva P., Leal C_, Aisa F. (1996). Early Amniocentesis at 10-12 weeks gestation. Prenat. Diagn., 16:307-312.
    /*ref*/Aula P., Karjalinen 0., Terano N., Vaara L., Seppala M. (1979). Safety and accuracy of
    /*ref*/midtrimester amniocentesis for prenatal diagnosis of genetic disorders. Ann. Clin. Res., 11:156-159.
    /*ref*/Simpson N., Dallaire L., Miller J., Siminovich L., Hammnerton J., Miller J., McKeen C. (1976). Prenatal diagnosis of genetic disease of Canada; report of a collaborative study. Can. Med. Ass. J., 115:739-745.
    /*ref*/Reece E.A. (1997). Amniocentese genética precoce e nos trimestres intermediarios.
    /*ref*/Segurança e resultados. In: Clinicam Obstétricas e Ginecológicas da América do Norte. Diagnóstico e Tratamento Fetal. Reece E.A. Vol 1. lnterlivros. Rio de Janeiro.
    /*ref*/Mennuti M., Brummond W., Criombleholme W., Shwartz R. (1980). Fetal maternal bleeding associated with genetic amniocentesis. Obstet. GynecoI., 55:48.
    /*ref*/Zolnierczyk P., Raczynski A., Lisawa J., Chazan B. (1997). Early amniocentesis transplacental needle passage safer than nontransplacental? Acta. Obstet. Gynecol. Scand., Supplement, 76(167):51.
    /*ref*/DATASUS. (1997). Banco de dados do Sistema Único de Saúde. Disponível na lnternet. http://www.datasus.saude.gov.brmarco2000
    Format
    application/pdf
    Type of digital resource
    info:eu-repo/semantics/article
    info:eu-repo/semantics/publishedVersion
    info:eu-repo/article/published
    info:eu-repo/article/published
    info:eu-repo/article/published
    URI
    https://repository.unad.edu.co/handle/10596/29902
    URL source
    http://hemeroteca.unad.edu.co/index.php/nova/article/view/513
    http://dx.doi.org/10.22490/24629448.513
    Collections
    • Revista Nova [1177]
    Usage guidesNormativityGuidelines for the advisor work direcorGuidelines for the student who loads degree workAPA 7 Edition StandardsTips APA 7 Edition Standards

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister
    GTM statisticsGTM statistics
    Indexed by:
    logo_Open Archives Initiative
    logo_Biblioteca Digital Ecuatoriana
    logo_OpenDOAR
    logo_Open ROAR
    logo_Google Scholar
    logo_Lyrasis
    logo_WorldCat
    logo_FAO
    logo_AGRIS
    logo_Alianza de Servicios de Información Agropecuaria
    logo_Siembra
    logo_Fedesarrollo
    logo_Colombia Digital
    logo_Hemeroteca UNAD
    logo_RED DE REPOSITORIOS LATINOAMERICANOS
    logo_OAIster
    logo_La Referencia
    logo_Open AIRE
    logo_Core
    logo_Base
    logo_CLACSO
    logo_OpenAlex
    logos isopreadGreat Work to PlaceIcontec - Great Work to Place

    Línea anticorrupción: 3232641617 ext. 1544

    En Bogotá D.C. (Colombia) Teléfono: 323 264 1617 - Línea gratuita nacional: 323 264 1617

    Institución de Educación Superior sujeta a inspección y vigilancia por el Ministerio de Educación Nacional

    Universidad Nacional Abierta y a Distancia UNAD de Colombia - © Copyright UNAD 2024

    Síguenos en: