Resistencia a la fractura de coronas dentales fabricadas análogamente vs tecnología cad-cam : Estudio In vitro
Fracture resistance of analogally made dental crowns vs cad-cam technology: In vitro study
Fracture resistance of analogally made dental crowns vs cad-cam technology: In vitro study
Share
Author
Insignares Ordoñez, Salvador
Díaz Caballero, Antonio
Beleño Quintero, Yureinys
Insignares Buelvas, Salin
Publisher
Universidad Colegio Mayor de CundinamarcaCitación
Bibliographic managers
Metadata
Show full item recordAbstract
Antecedentes. La resistencia a la fractura de las coronas puede tener influencia en su ocurrencia, de acuerdo con el método de fabricación usado, ya sea análogamente o por medio de tecnología Cad-Cam. Objetivo. Comparar la resistencia a la fractura de las coronas individuales realizadas por dos métodos de fabricación, bajo diseño asistido por ordenador y fabricación computarizada (CAD-CAM) e inyectadas. Método. Estudio in vitro. Tamaño de la muestra 20 coronas en dos grupos: 10 coronas bajo tecnología CAD-CAM y 10 coronas inyectadas. Fueron sometidas a cargas compresivas en una máquina de ensayos universal, con una velocidad de 1mm/min y una carga de celda de 5kN hasta obtener la fractura máxima de estas. Los datos se analizaron estadísticamente utilizando las pruebas Shapiro Wilk, Mann Whitney p=0,05. Resultados. Las coronas fabricadas por Cad-Cam obtuvieron un mínimo de 602,5 Newton y un máximo de 1093 Newton, mientras que las coronas fabricadas análogamente obtuvieron un mínimo de 525,2 Newton y un máximo de 1773 Newton en el experimento con la máquina de ensayo universal para lograr su fractura. Se obtuvo una diferencia significativa en la prueba de resistencia a la factura entre ambos métodos de fabricación (p <0,001). Conclusión. Las coronas de Disilicato de litio prensadas obtuvieron una mayor resistencia a la fractura que las coronas fabricadas via CAD-CAM. Background. The fracture resistance of the crowns may have an influence on their appearance, according to the method of making them, either analogously or by means of Cad-Cam technology. Objective. To compare the resistance to the fracture of the individual crowns made by two manufacturing methods, under computer-aided design and computerized manufacturing (CAD-CAM) and injected. Methods. In vitro study. Sample size 20 crowns in two groups: 10 crowns using CAD-CAM technology and 10 crowns injected. Crowns were subjected to compressive loads in a universal testing machine, with a speed of 1mm / min and a cell load of 5kN until obtaining the maximum bill for these. Data were statistically analyzed using the Shapiro Wilk tests, Mann Whitney p = 0.05. Results. Crowns manufactured by Cad-Cam obtained a minimum of 602.5 Newton and a maximum of 1093 Newton, while the crowns manufactured analogously obtained a minimum of 525.2 Newton and a maximum of 1773 Newton in the experiment with the machine Universal test to achieve their fracture. A significant difference was obtained in the invoice resistance test between both manufacturing methods (p <0.001). Conclusion. Pressed Lithium Disilicate crowns obtained higher fracture resistance than crowns under design and manufacturing by computer (CAD-CAM).
College
https://hemeroteca.unad.edu.co/index.php/nova/article/view/5296/5094Format
application/pdfType of digital resource
info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersion
info:eu-repo/article/published
info:eu-repo/article/published
info:eu-repo/article/published
URL source
https://hemeroteca.unad.edu.co/index.php/nova/article/view/5296http://dx.doi.org/10.22490/24629448.5296
Collections
- Revista Nova [1177]