• español
    • English
    • français
    • português
A+A-
  • English 
    • español
    • English
    • français
    • português
    • Usage guides
      • Guidelines for the advisor work direcor
      • Guidelines for the student who loads degree work
      • APA 7 Edition Standards
      • Tips APA 7 Edition Standards
    • Users
    View Item 
    •   National Open and Distance University UNAD
    • Producción Científica
    • Sello Editorial UNAD
    • Revista RIAA
    • View Item
    •   National Open and Distance University UNAD
    • Producción Científica
    • Sello Editorial UNAD
    • Revista RIAA
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Reducción de la demanda química de oxígeno, coliformes, mohos y levaduras en mucílago de café mediante electrocoagulación

    Reduction in chemical oxygen demand, coliforms, molds and yeast in coffee mucilage through electrocoagulation;
    Reducao da demanda quimica de oxigenio, coliformes, mofos e leveduras em mucilagem de cafe por eletrocoagulacao

    Reduction in chemical oxygen demand, coliforms, molds and yeast in coffee mucilage through electrocoagulation

    Thumbnail
    QRCode
    Share
    Author
    Orozco, Luis Felipe
    Castro-Ríos, Katherin
    Taborda Ocampo, Gonzalo
    Publisher
    Sello Editorial UNAD

    Citación

           
    TY - GEN T1 - Reduction in chemical oxygen demand, coliforms, molds and yeast in coffee mucilage through electrocoagulation T1 - Reducción de la demanda química de oxígeno, coliformes, mohos y levaduras en mucílago de café mediante electrocoagulación T1 - Reducao da demanda quimica de oxigenio, coliformes, mofos e leveduras em mucilagem de cafe por eletrocoagulacao AU - Orozco, Luis Felipe AU - Castro-Ríos, Katherin AU - Taborda Ocampo, Gonzalo UR - https://repository.unad.edu.co/handle/10596/47324 PB - Sello Editorial UNAD AB - ER - @misc{10596_47324, author = {Orozco Luis Felipe and Castro-Ríos Katherin and Taborda Ocampo Gonzalo}, title = {Reduction in chemical oxygen demand, coliforms, molds and yeast in coffee mucilage through electrocoagulationReducción de la demanda química de oxígeno, coliformes, mohos y levaduras en mucílago de café mediante electrocoagulaciónReducao da demanda quimica de oxigenio, coliformes, mofos e leveduras em mucilagem de cafe por eletrocoagulacao}, year = {}, abstract = {}, url = {https://repository.unad.edu.co/handle/10596/47324} }RT Generic T1 Reduction in chemical oxygen demand, coliforms, molds and yeast in coffee mucilage through electrocoagulation T1 Reducción de la demanda química de oxígeno, coliformes, mohos y levaduras en mucílago de café mediante electrocoagulación T1 Reducao da demanda quimica de oxigenio, coliformes, mofos e leveduras em mucilagem de cafe por eletrocoagulacao A1 Orozco, Luis Felipe A1 Castro-Ríos, Katherin A1 Taborda Ocampo, Gonzalo LK https://repository.unad.edu.co/handle/10596/47324 PB Sello Editorial UNAD AB OL Spanish (121)
    Bibliographic managers
    Refworks
    Zotero / EndNote / Mendeley
    BibTeX
    CiteULike
    Metadata
    Show full item record
    Abstract
    El mucílago y la pulpa de café, son subproductos semilíquidos involucrados en la generación de aguas residuales con alta concentración de materia orgánica y diversas especies de microorganismos, afectando negativamente la eficiencia de los tratamientos tradicionales, que requieren hasta cinco meses para la descontaminación total de este tipo de aguas. Esto demanda la evaluación de diferentes técnicas de tratamiento, que mejoren la eficiencia de los procesos tradicionales. Se evaluó la electrocoagulación con electrodos Fe/Al, 2.3 A y pH natural, en la reducción de la demanda química de oxígeno y algunos microorganismos, presentes en mucílago de café. El proceso electroquímico propició una remoción máxima de 93% para bacterias coliformes, mohos y levaduras, en un tiempo de tratamiento de 50 min. La reducción de la demanda química de oxígeno fue 32% para la muestra sin diluir, 45% para la muestra diluida al 50% (v/v) y 51%, para las muestra diluida al 25% (v/v); indicando una mejor eficiencia con la disminución de la materia orgánica. El consumo energético fue inferior a los 0.083 kWh/m3, para las muestras analizadas. Esta técnica es una alternativa adecuada para el pre-tratamiento o reutilización de aguas contaminadas con mucílago de café.
     
     
    Coffee pulp and mucilage are semi-liquid by-products involved in the generation of residual waters with a high concentration of organic matter and diverse species of microorganisms which negatively affect the efficiency of traditional treatment and require up to five months for total decontamination of these waters. This demands the testing of different treatment methods that can improve the efficiency of traditional processes. Electrocoagulation was tested with Fe/Al electrodes, 2.3 A and natural pH in a reduction in chemical oxygen demand and other microorganisms present in the coffee mucilage. The electrochemical process produced a maximum removal of 93% for coliform bacteria, molds and yeasts with a treatment time of 50 min. The reduction in chemical oxygen demand was 32% for the undiluted sample, 45% for the sample diluted to 50% (v/v), and 51% for sample diluted to 25% (v/v); indicating there is an increase in efficiency with a decrease in organic matter. The energy consumption was less than 0.083 kWh/m3 for the samples analyzed. This method is a viable alternative for the pre-treatment or reutilization of waters contaminated with coffee mucilage.
     
    A mucilagem e polpa de cafe sao subprodutos semiliquidos envolvidos na geracao de efluentes com elevado teor de materia organica e de varias especies de microrganismos, impactando adversamente a eficacia dos tratamentos tradicionais, que precisam de ate cinco meses para a descontaminacao total deste tipo de agua. Isto requer a avaliacao de diferentes tecnicas de tratamento, que melhorem a eficiencia dos processos tradicionais. Avaliou-se a eletrocoagulacao com eletrodos Fe/Al, 2.3 e pH natural, na reducao da demanda quimica de oxigenio e alguns micro-organismos presentes na mucilagem do cafe. O processo eletroquimico levou a uma remocao maxima de 93% para bacterias coliformes, mofos e leveduras, em um tempo de tratamento de 50 min. A reducao da demanda quimica de oxigenio foi de 32% para a amostra nao diluida, 45% para a amostra diluida a 50% (v/v) e 51% para a amostra diluida a 25% (v/v), indicando melhor eficiencia com a reducao do material organico. O consumo de energia foi inferior a 0.083 kWh/m3 para as amostras analisadas. Esta tecnica e uma alternativa adequada para o pre-tratamento ou reutilizacao de aguas contaminadas com mucilagem de cafe.
     
    College
    https://hemeroteca.unad.edu.co/index.php/riaa/article/view/975/958
    Format
    application/pdf
    Type of digital resource
    info:eu-repo/semantics/article
    info:eu-repo/semantics/publishedVersion
    URI
    https://repository.unad.edu.co/handle/10596/47324
    URL source
    https://hemeroteca.unad.edu.co/index.php/riaa/article/view/975
    http://dx.doi.org/10.22490/21456453.975
    Collections
    • Revista RIAA [1154]
    Usage guidesNormativityGuidelines for the advisor work direcorGuidelines for the student who loads degree workAPA 7 Edition StandardsTips APA 7 Edition Standards

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister
    GTM statisticsGTM statistics
    Indexed by:
    logo_Open Archives Initiative
    logo_Biblioteca Digital Ecuatoriana
    logo_OpenDOAR
    logo_Open ROAR
    logo_Google Scholar
    logo_Lyrasis
    logo_WorldCat
    logo_FAO
    logo_AGRIS
    logo_Alianza de Servicios de Información Agropecuaria
    logo_Siembra
    logo_Fedesarrollo
    logo_Colombia Digital
    logo_Hemeroteca UNAD
    logo_RED DE REPOSITORIOS LATINOAMERICANOS
    logo_OAIster
    logo_La Referencia
    logo_Open AIRE
    logo_Core
    logo_Base
    logo_CLACSO
    logo_OpenAlex
    logos isopreadGreat Work to PlaceIcontec - Great Work to Place

    Línea anticorrupción: 3232641617 ext. 1544

    En Bogotá D.C. (Colombia) Teléfono: 323 264 1617 - Línea gratuita nacional: 323 264 1617

    Institución de Educación Superior sujeta a inspección y vigilancia por el Ministerio de Educación Nacional

    Universidad Nacional Abierta y a Distancia UNAD de Colombia - © Copyright UNAD 2024

    Síguenos en: