• español
    • English
    • français
    • português
A+A-
  • English 
    • español
    • English
    • français
    • português
    • Usage guides
      • Guidelines for the advisor work direcor
      • Guidelines for the student who loads degree work
      • APA 7 Edition Standards
      • Tips APA 7 Edition Standards
    • Users
    View Item 
    •   National Open and Distance University UNAD
    • Producción Científica
    • Sello Editorial UNAD
    • Revista RIAA
    • View Item
    •   National Open and Distance University UNAD
    • Producción Científica
    • Sello Editorial UNAD
    • Revista RIAA
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Determinación del punto de carga cero y punto isoeléctrico de dos residuos agrícolas y su aplicación en la remoción de colorantes

    Determination of the point of zero charge and isoelectric point of two agricultural wastes and their application in the removal of colorants;
    Determinação do ponto de carga zero e ponto isoelétrico de dois resíduos agrícolas e sua aplicação na remoção de corantes.

    Determination of the point of zero charge and isoelectric point of two agricultural wastes and their application in the removal of colorants

    Thumbnail
    QRCode
    Share
    Author
    Amaringo Villa, Fredy Alberto
    Publisher
    Sello Editorial UNAD

    Citación

           
    TY - GEN T1 - Determination of the point of zero charge and isoelectric point of two agricultural wastes and their application in the removal of colorants T1 - Determinación del punto de carga cero y punto isoeléctrico de dos residuos agrícolas y su aplicación en la remoción de colorantes T1 - Determinação do ponto de carga zero e ponto isoelétrico de dois resíduos agrícolas e sua aplicação na remoção de corantes. AU - Amaringo Villa, Fredy Alberto UR - https://repository.unad.edu.co/handle/10596/47330 PB - Sello Editorial UNAD AB - ER - @misc{10596_47330, author = {Amaringo Villa Fredy Alberto}, title = {Determination of the point of zero charge and isoelectric point of two agricultural wastes and their application in the removal of colorantsDeterminación del punto de carga cero y punto isoeléctrico de dos residuos agrícolas y su aplicación en la remoción de colorantesDeterminação do ponto de carga zero e ponto isoelétrico de dois resíduos agrícolas e sua aplicação na remoção de corantes.}, year = {}, abstract = {}, url = {https://repository.unad.edu.co/handle/10596/47330} }RT Generic T1 Determination of the point of zero charge and isoelectric point of two agricultural wastes and their application in the removal of colorants T1 Determinación del punto de carga cero y punto isoeléctrico de dos residuos agrícolas y su aplicación en la remoción de colorantes T1 Determinação do ponto de carga zero e ponto isoelétrico de dois resíduos agrícolas e sua aplicação na remoção de corantes. A1 Amaringo Villa, Fredy Alberto LK https://repository.unad.edu.co/handle/10596/47330 PB Sello Editorial UNAD AB OL Spanish (121)
    Bibliographic managers
    Refworks
    Zotero / EndNote / Mendeley
    BibTeX
    CiteULike
    Metadata
    Show full item record
    Abstract
    Los residuos agroindustriales han mostrado ca­racterísticas adsorbentes, y con ello su posible uso alternativo para la remoción de contaminan­tes disueltos presentes en los efluentes industriales. La caracterización química de la superficie del material adsorbente permite establecer su capacidad para retener ciertos contaminantes iónicos. En el presente estudio se determinó el punto de carga cero (PZC) y el punto isoeléctrico (IEP) de dos residuos agrícolas, cascarilla de arroz y corteza de coco, con el fin de establecer la distribución de cargas sobre su superficie y posteriormente evaluar su capacidad de remoción de colorantes aniónicos o catiónicos disueltos. Para ello se utilizó el método de la deriva del pH y del potencial zeta, variando el intervalo de pH entre 2.0 y 11 y manteniendo constante las demás variables. Para la cascarilla de arroz se obtuvo un PZC de 5.40 y un IEP de 9.10 y para la corteza de coco un PZC de 4.61 y un IEP de 9.45, señalando una distribución de cargas predominantemente positivas sobre su superficie. La posterior evaluación de esta característica comprobó su afinidad para la remoción de colorantes iónicos. Se alcanzó una remoción del 93% del colorante catiónico rojo básico 46 (RB46) a un pH mayor a 5.0 y una retención del 73% del colorante aniónico rojo 40 (R40) a un pH = 2.0 sobre cascarilla de arroz. La determinación del PZC y IEP de los adsorbentes posibilita el establecimiento de las mejores condiciones para la adsorción de colorantes iónicos en solución.
     
     
    Agro-industrial wastes have shown adsorptive properties and therefore can be considered as a potential alternative for the removal of dissolved contaminants present in industrial effluents. The chemical composition of the absorbate`s surface allows it to stablish its capacity to retain certain ionic contaminants. This study, determinates the point of zero charge (PZC) and the isoelectric point (IEP) of two agricultural wastes, rice husks and coconut husk, with the end of establishing the distribution of charges on the surface and subsequently to evaluate their capacity for the removal dissolved anionic or cationic colorants. In order to accomplish this, the study utilized the methods of pH drift and zeta potential varying the pH interval between 2.0 and 11 and maintaining the other variables at a constant. A PZC of 5.40 and an IEP of 9.10 were obtained for the rice husk, and a PZC of 4.61 and an IEP of 9.45 for the coconut husk, indicating a distribution of predominately positive charge on the surface. Further study of this characteristic confirmed its affinity for the removal of ionic colorants. The rice husk showed a removal of 93% of the cationic colorant basic red 46 (RB46) with at a pH higher than 5.0 and a retention of 73% of the anionic red 40 colorant(R40) at pH = 2.0 on rice husks. The determination of the PZC and IEP of the adsorbents allows for the establishment of better conditions for the adsorption of ionic colo­rants in solution.
     
    Os resíduos agroindustriais têm se mostrado com características absorventes e com ele seu possível uso alternativo para a remoção de contaminantes dissolvidos presentes nos efluentes industriais. A ca­racterização química da superfície do material absorvente permite estabelecer sua capacidade para reter certos contaminantes iônicos. Na pesquisa que se segue determinou-se o ponto de carga zero (PCZ) e o ponto isoelétrico (PIE) dos resíduos agrícolas, casca de arroz e de coco, com a finalidade de estabelecer a distribuição de cargas sobre a superfície e posteriormente avaliar sua capacidade de remoção de corantes aniônicos ou catiônicos dissolvidos. Para isso utilizou-se o método da deriva de pH e de potencial Zeta, variando o intervalo de pH entre 2 e 11 mantendo constantemente as demais variáveis. Para a casca do arroz se obteve um PCZ de 5.40 e um PIE de 9.10 e para a casca de coco um PCZ de 4.61 e um PIE de 9.45, apontado uma distribuição de cargas predominantemente positiva sobre a sua superfície. A avaliação posterior desta característica comprovou sua finalidade para a remoção de corantes iônicos. Alcançou-se uma remoção de aproximadamente de 93% do corante catiônico vermelho básico (VB46) e um pH maior que 5.0 e uma retenção total de aproxi­madamente 73% do corante aniônico vermelho 40 (V40) a um pH = 2.0 sobre a casca do arroz. A determinação do PCZ e do PIE dos absorventes possibilita o estabelecimento de melhores condições para a absorção de corantes iônicos na solução.
     
    College
    https://hemeroteca.unad.edu.co/index.php/riaa/article/view/982/963
    Format
    application/pdf
    Type of digital resource
    info:eu-repo/semantics/article
    info:eu-repo/semantics/publishedVersion
    URI
    https://repository.unad.edu.co/handle/10596/47330
    URL source
    https://hemeroteca.unad.edu.co/index.php/riaa/article/view/982
    http://dx.doi.org/10.22490/21456453.982
    Collections
    • Revista RIAA [1154]
    Usage guidesNormativityGuidelines for the advisor work direcorGuidelines for the student who loads degree workAPA 7 Edition StandardsTips APA 7 Edition Standards

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister
    GTM statisticsGTM statistics
    Indexed by:
    logo_Open Archives Initiative
    logo_Biblioteca Digital Ecuatoriana
    logo_OpenDOAR
    logo_Open ROAR
    logo_Google Scholar
    logo_Lyrasis
    logo_WorldCat
    logo_FAO
    logo_AGRIS
    logo_Alianza de Servicios de Información Agropecuaria
    logo_Siembra
    logo_Fedesarrollo
    logo_Colombia Digital
    logo_Hemeroteca UNAD
    logo_RED DE REPOSITORIOS LATINOAMERICANOS
    logo_OAIster
    logo_La Referencia
    logo_Open AIRE
    logo_Core
    logo_Base
    logo_CLACSO
    logo_OpenAlex
    logos isopreadGreat Work to PlaceIcontec - Great Work to Place

    Línea anticorrupción: 3232641617 ext. 1544

    En Bogotá D.C. (Colombia) Teléfono: 323 264 1617 - Línea gratuita nacional: 323 264 1617

    Institución de Educación Superior sujeta a inspección y vigilancia por el Ministerio de Educación Nacional

    Universidad Nacional Abierta y a Distancia UNAD de Colombia - © Copyright UNAD 2024

    Síguenos en: